News and Information |
|
NEW ARRIVALS
|
|
Stabimatic Company Ltd UK |
|
|
|
|
|
GS Series , true online, single phase
Key Features |
|
MODEL |
|
GS600 |
GS
1000 |
GS
2000 |
GS
3000 |
GS
5000 |
GS
8000 |
GS
10000 |
GS
12000 |
|
600VA |
1000VA |
2000VA |
3000VA |
5000VA |
8000VA |
10000VA |
12000VA |
INPUT |
Voltage (Vac) |
150-290 |
Frequency (Hz) |
50/60±10% (Auto. Sensing |
Phase |
Single |
Input Power Factor |
>0.98 |
OUTPUT |
Voltage (Vac) |
220 |
Load Power Factor Range |
0.5 Lagging to Unity within KW rating of unit |
Wave Form |
Sine Wave |
Frequency Stability |
±0.5% (Free Running) |
Synchronization |
Slow Rate: IHZ/Sec. Max. Synchronization window±5% |
Transfer Time |
0 ms |
Crest Factor |
3 : 1 |
Efficiency |
>90% |
>90% |
>90% |
>90% |
>92% |
>92% |
>92% |
>92% |
Run-time (Full Load) |
>12
min. |
>12
min. |
>12
min. |
>12
min. |
>12
min. |
>12
min. |
>12
min. |
>10
min. |
DC start |
Yes |
BATTERY |
Type |
Sealed Maintenance Free Lead Acid |
Recharge Time |
6 Hours To 90% |
DISPLAY |
LED |
Utility Battery, Inverter, Over Load, Load/battery level, Fault conditions |
LCD |
Input Voltage, Output Voltage, Output Frequency, Load Percentage,
Inner Ambient Temperature, Battery Voltage, Fault |
PROTECTIONS |
Overload |
AC Mode: 1) <105% continuously. |
2) 105%-120% delay 15 minutes before switching to bypass. |
3) 120-150% delay 30 seconds before switching to bypass. |
4) >150% immediately switching to bypass. |
Backup Mode:>105% delay 1.5 seconds then completely shutdown. |
Short Circuit |
Hold whole system |
Overheat |
Switch to Bypass |
High Voltage Trip-Off |
Switch to Backup mode |
Battery Low |
Alarm and Switch off |
Noise Suppression |
EMI/RFI Filtering |
Spike Suppression |
Compiles with IEEE 587.1 Category A, 200 Joules, 6.5KA for 230V units. |
ALRAMS |
Audible and Visual |
Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions |
ENVIORNMENT |
Operating Temperature Range |
0C-40C |
Temperature Warning |
25C, Ambient temperatures above this range will reduce battery life. |
Altitude |
0-200m up to 40C. 300m up to 35C. |
Humidity |
99% RH Maximum, Non-condensing |
Noise |
<50dB (at 1 meter) |
COMPUTER INTERFACE |
Interface Type |
Standard RS232 Interface |
Protocol |
Maga Tec RUPS II, II and Basic Photo-couple Contact Signal Pattern |
SNMP Adaptability |
Slot for Standard SNMP Card Available (option) |
Standard Bundled Software Compatibility |
For Novell Netware, Windows95/98, Windows NT, Windows 2000 |
Optional Software |
For UNIX, etc. |
SAFETY CONFORMANCE |
Quality Assurance |
ISO 9001 certified company |
Safety Standard |
EN50091-1, TUV/GS |
EMC Standard |
EN50091-2, EN61000-3-2, EN1000-3-3 |
Marks |
CE, TUV/GS |
Above specifications are subject to change without prior notice.
Trademarks of Mega Tec. RUPSII, Novell Netware, Windows and UNIX are registered trademarks of their respective companies
MULTI PROTECTION
-
Over voltage trip circuit
- Complete noise-interference proof architecture
- State-of-the-art, IGBT technology
- Modem/10 base-T network port ,
- Over load protection
- Inverter feedback failure protection
- Inductive load acceptable
- Short Circuit protection
-
Over temperature protection
|
|
|